Home / Knowledge / ETA for asbestos encapsulation with Impermax 2K and Rayston X5
ETA for asbestos encapsulation with Impermax 2K and Rayston X5

An ETA for asbestos encapsulation covers a specific named kit. It does not remove the need for the aliphatic finish.
An asbestos encapsulation ETA applies to the membrane that carries it. The 2026 Krypton Chemical catalogue lists Impermax 2K (two-component biobased polyurethane) with ETA 10/0296, 25 years (W3), a root-penetration certificate and a certificate of asbestos-fibre encapsulation. Polyurea Rayston X5 (expandable polyurea) also has an asbestos encapsulation certificate. The waterproofing catalogue cites a 1,500 m² fibre-cement roof in Mallorca and refers to ETA 06/0263 on the Impermax 1K family for a 10- or 25-year encapsulation procedure. A certificate issued for a floor system cannot be carried over to these roofs.
What an asbestos encapsulation ETA covers
Impermax 2K is a fast-curing two-component biobased polyurethane able to bridge fissures. Its applications in the 2026 catalogue include general waterproofing, concrete and metal, parking-deck roofs, green roofs and asbestos encapsulation, and it requires a final aliphatic protective coating. Polyurea Rayston X5 expands to several times its volume and is designed for irregular dry supports, including corrugated metal and fibre-cement. It too must be protected with an aliphatic topcoat where the data sheet requires it.
Encapsulation is not removal. The catalogue procedure covers cleaning, encapsulation and waterproofing of the fibre-cement, so that activities inside the building can continue without interruption.
Specifying asbestos encapsulation
A clear specification identifies fibre-cement as the support, names Impermax 2K or Polyurea Rayston X5 together with its chemical type, and adds the aliphatic finish given in the current TDS. Once the data sheet has been checked, the calculator helps you size the area.
Product details are on the Impermax 2K and Polyurea Rayston X5 entries, and the full procedure is on the asbestos encapsulation application page. Data sheets and certificates are in documents, and the calculator helps you size the area.
External reference: EOTA — European Technical Assessments.
A photograph of a fibre-cement roof is no evidence of certification; check the certificate for the named product.
Consumption, mix ratio and overcoat interval are given in the TDS rather than in this article. Start with the current documents, choose the primer, then specify the membrane and the aliphatic finish.
This article is general technical guidance from Krypton Chemical and does not replace the current technical data sheet (TDS), the safety data sheet (SDS) or the project specification. Pack sizes, mix ratio and consumption in kg/m² are given in the current TDS; with those figures, the calculator helps you estimate quantities for your area.